UK Supplier of Data Acquisition & Thermal Imaging systems, software and services

Search

20kW Programmable DC Power Supplies

  • 20kW Programmable DC Power Supplies
  • 0 to 800/1500 V output voltage
SKU HPS Series Category
Manufacturer:

Call for price

Description

20kW Programmable DC Power Supplies: The HPS Series from B&K Precision

The HPS Series Programmable DC Power Supplies deliver 20 kW of clean output power with high efficiency, all within a compact 3U form factor. These power supplies are ideal for Automated Test Equipment (ATE) applications, offering a wide output voltage range of up to 1500 V. Multiple units can be connected in parallel to achieve a total output power of 160 kW.

The power supplies feature a 5-inch touchscreen that provides intuitive controls and displays both set and measured values, including simulated internal resistance. A script function allows the power supply to execute a sequence of user-defined voltage and current steps based on specified commands.

Built-in protection features, such as under-voltage protection, safeguard both the power supply and the device under test. Furthermore, adjustable voltage and current slew rates, along with configurable output on/off timer functions, give users enhanced control over operations. LabVIEW™ drivers are included to facilitate instrument control from a PC, and output voltage and current can be logged directly onto a USB flash drive.

Product Features

  • 5-inch TFT touchscreen display for intuitive control
  • High power density, 20 kW in a 3U form factor
  • Efficiency up to 94%
  • Built-in voltage and current measurement
  • Master/slave mode provides up to 160 kW of output power with 8 units connected in parallel
  • Galvanically isolated analogue control and monitoring interface
  • OVP, OCP, OPP, UVP (under voltage protection), and key lock function
  • Configurable voltage and current rise time
  • Fast transient response time < 3 ms
  • Thermostatically-controlled fans help minimize noise
  • Simulate the output of photovoltaic arrays
  • Remote sense to compensate for voltage drop
  • Datalogging directly to a USB flash drive
  • Output on/off timer
  • RS232 and LAN interfaces
  • LabVIEW™ drivers included
  • 3-phase 208 VAC or 400 VAC input configurations available

 

Suitable for applications in aerospace, electric vehicle (EV), solar, and green technology industries.

Model HPS20K800 HPS20K1500
Output Rating
Output Voltage 0 to 800 V 0 to 1500 V
Output Current 0 to 25 A 0 to 13.4 A
Output Power 20 kW
Line Regulation
Voltage 160 mV 300 mV
Current 5 mA 3 mA
Load Regulation
Voltage 420 mV 770 mV
Current 33 mA 27 mA
Ripple and Noise (20 Hz to 20 MHz)
Voltage p-p 350 mV 900 mV
Voltage rms 150 mV 200 mV
Current  rms *1 25 mA 12 mA
Readback Resolution
Voltage Range 20 V to 99.99 V 10 mV
100.0 V to 999.9 V 0.1 V
1000 V to 1500 V - 1 V
Current Range 0 A to 9.999 A 1 mA
10.00 A to 25 A 10 mA
Programming Accuracy
Voltage ≤ 800 mV ≤ 1.5 V
Current ≤ 50 mA ≤ 30 mA
Output Response Time *2
Rise Time Full Load ≤ 40 ms ≤ 6 ms
No Load ≤ 10 ms ≤ 5 ms
Fall Time Full Load ≤ 60 ms ≤ 25 ms
No Load ≤ 10 s ≤ 1 s
208 AC Input
Nominal Input Voltage 208 VAC
Input Range 187 to 229 VAC
Frequency 47 to 63 Hz
Phase 3 phase
Protection
OVP Range 0 to 960 V 0 to 1800 V
General
Remote Sense Compensation 80 V 150 V
Transient Response Time *3 ≤ 3 ms
Command Response Time *4 10 ms
Efficiency *5 94%
Power Factor > 0.7
Output Terminal Isolation 2000 V
Inrush Current *6 76 A
Leakage Current < 35 mA
I/O Interfaces RS232, LAN,
Analogue (Galvanically isolated DB25)
Analogue Programming (typical) Input impedance: 1 MΩ
Maximum input voltage 25 V
Response time < 10 ms
Temperature Ratings Operation 0 ºC to 50 ºC
Storage -20 ºC to 70 ºC
Operating Humidity < 80%
Altitude < 2000 m
Environment Installation category II, pollution degree 2
Dimensions (W x H x D) 482 x 132.5 x 614.7 mm
Weight 37 Kg
Warranty 3 Years
Standard Accessories Test report & certificate of calibration
Regulatory Compliance
Safety Low Voltage Directive (LVD) 2014/35/EU,
EN61010-1:2010 + A1:2019
Electromagnetic Compatibility EMC Directive 2014/30/EU, EN61326-1:2013

 

*1 When output power > 1.0% of full power.
*2 From 10% to 90% or from 90% to 10% of total voltage excursion.
*3 Time for output voltage to recover within 0.5% ±25 mV of its rated output.
*4 Typical time required for output to begin to change following receipt of command data.
*5 At nominal line voltage and max load.
*6 Applies to rated input voltage. The inrush current only occurs when first connecting to the grid.