Description
TEAC TC-MFSR(T)-G Compression Load Cell.
It is a small load cell with a flat load point. Ideal for pressurizing control of bonding machine.
Small construction, flat load point.
Maximum rated capacity of 50N
Call for price
TEAC TC-MFSR(T)-G Compression Load Cell.
It is a small load cell with a flat load point. Ideal for pressurizing control of bonding machine.
Small construction, flat load point.
Model |
Unit |
Rated Capacity (RC) |
||||||||||||
TC-MFSR(T)-G | N | 0.5 | 1 | 1.5 | 2 | 3 | 5 | 10 | 20 | 50 | 100 | 200 | 500 | |
kN | 1 | 2 | 3 | 5 | 10 | 20 | 30 | 50 | 100 | 200 | 300 | 500 | 1000 |
Rate Capacity (RC) |
Resonance Frequency |
Weight |
|
20 N | 2.04 kgf | 23 KHz | 2 g |
50 N | 5.1 kgf | 23 KHz | 2 g |
Model |
TC-MFSR(T)-G |
Safe Overload | 120 % R.C. |
Rated Output (R.O.) | 1 mV/V ±30 % |
Non-Linearity | 0.5 % R.O. |
Hysteresis | 0.5 % R.O. |
Non-Repeatability | 0.3 % R.O. |
Excitation Voltage | 6 V |
Input Resistance | 350 Ω ±20 Ω |
Output Resistance | 350 Ω ±20 Ω |
Insulation Resistance | >1000 MΩ |
Compensated Temperature Range | 0 °C to 60 °C |
Safe Temperature Range | –10 °C to 80 °C |
Temperature Effect on the Zero Signal | 2 % R.O. / 10 °C |
Temperature Effect on the Output | 1 % R.C. / 10 °C |
Cable | Ø 2 mm shielded 6-conductor wire, robot-cable, 3 m direct connection |
Material | Beryllium copper |
TEDS | Built-in |
Environmental Regulations | RoHS/REACH |
DAQLOG Systems Ltd
Brixham Laboratory
Freshwater Quarry, Brixham, TQ5 8BA
Tel: 01803 611 854