Description
Electrochemical Impedance Spectroscopy (EIS) Battery Analyser from B&K Precision.
The BA8100 is designed for diagnosing single battery cells or battery stacks up to 80 V. These instruments accurately measure impedance and phase. Auxiliary measurements include voltage, current, capacitance, inductance, as well as quality factor and more.
Using the included Frequency Response Analysis software, the BA8100 can perform EIS tests with a frequency range of 50 mHz to 10 kHz. The impedance spectrum can be evaluated through the Nyquist and Bode plot tools to determine effective series resistance (ESR) and track battery health. The included self-test fixture is used to verify the instrument’s performance or compensate for resistance introduced by the test leads.
Product Features
- Fixed frequency measurements from the front panel
- Swept frequency using included software
- Maximum input voltage of 80 V
- Programmable DC and AC current settings
- EIS frequency range of 50 mHz to 10 kHz
- Impedance Z, phase angle θ, voltage and current measurements
- Simple 4-wire test connection
- LAN, USB (COM), and RS232 interfaces standard
- 3 year warranty
Note: All specifications apply to the unit after a temperature stabilization time of 30 minutes over an ambient temperature range of 23 °C ± 5 °C.
Input
|
Voltage |
0.5 V to 80 V |
Power |
200 W maximum (dissipated by internal load) |
Settings
|
Current |
DC |
0.5 A to 3 A (dissipated by internal load) |
Modulating AC Current |
50 mArms to 300 mArms (10% of DCA typical) |
Modulating Frequency |
Range |
0.05 Hz to 10 kHz |
Resolution (Auto) |
0.001 Hz to 0.1 Hz |
Accuracy |
0.01% of setting |
Displayed Parameters
|
Primary |
X, Z, V, I, Freq. |
Secondary |
Rs, Rp, Xs, Xp, Cs, Cp, Ls, Lp, Q, D, and θ |
Measurements
|
Voltage 4-wire |
Range |
0 V to 80 V |
Resolution |
0.1 mV |
Accuracy (ACI = 0) (1) |
0.05% of reading + 0.05% of full scale |
DC Sink Current |
Range |
0 A to 3 A |
Resolution |
0.1 mA |
Accuracy (ACI = 0) (1) |
0.5% of reading + 0.1% of full scale |
Resistance R
Auto sampling interval (8 to 10 cycles) and auto range enabled |
Displayed Digits |
5 digits including sign |
Resolution |
1 μΩ |
Accuracy (10 Hz to 10 kHz) |
±(0.5% of reading + 5 μΩ) |
Impedance Z
Auto sampling interval (8 to 10 cycles) and auto range enabled |
Displayed Digits |
5 digits including sign |
Resolution |
1 μΩ |
Accuracy (10 Hz to 10 kHz) |
±(0.5% of reading + 5 μΩ) |
Phase Angle θ |
Range |
-180° to 180° |
Resolution |
0.01° |
Accuracy |
±0.3° |
General
|
AC Input |
100 VAC to 240 VAC, 50/60 Hz |
UUT Connector |
4-terminal banana jack |
IO Interfaces |
LAN, USB (Virtual COM), RS232 |
Operating Temperature |
30° C to 40° C |
Storage Temperature |
-10° C to 50° C |
Dimensions (W x H x D) |
215 x 90 x 370 mm |
Weight |
4.5 Kg |
Software |
Bundled software for fixed or frequency sweep, Nyquist and Bode plots |
Warranty |
3 years |
Standard Accessories |
AC Power cord, kelvin clip test leads, calibration certificate,
calibration test fixture (TLC81) |
(1) The accuracy of DC voltage and current should be under no modulation condition (i.e. AC current = 0).