DATAQ Data Acquisition & Loggers Archives - DAQLOG Systems Ltd Supplier of data acquisition and thermal imaging cameras Wed, 20 May 2026 09:50:25 +0000 en-GB hourly 1 https://wordpress.org/?v=7.0 https://daqlogsystems.co.uk/wp-content/uploads/favicon-196-100x100.png DATAQ Data Acquisition & Loggers Archives - DAQLOG Systems Ltd 32 32 DI-4108-M and DI-4208-M Rugged High-Speed USB/Ethernet Data Loggers https://daqlogsystems.co.uk/product/dataq-di-4108-m-and-di-4208-m-rugged-high-speed-usb-ethernet-data-loggers/ Fri, 31 Jan 2025 13:05:41 +0000 https://daqlogsystems.co.uk/?post_type=product&p=7896 High-Speed USB and Ethernet Data Loggers DI-4108-M & DI-4208-M from DATAQ.
Expandable to 128 chs, up to 16-bit resolution where applicable, 160,000 S/s throughput *1.

The post DI-4108-M and DI-4208-M Rugged High-Speed USB/Ethernet Data Loggers appeared first on DAQLOG Systems Ltd.

]]>
High-Speed USB and Ethernet Data Loggers, DI-4108-M and DI-4208-M from DATAQ Instruments.

DI-4108-M Programmable ranges: ±200, ±500 mV, ±1, ±2, ±5, ±10 V full scale
DI-4208-M Programmable ranges: ±2, ±5, ±10, ±20, ±50, ±100 V full scale

Product Features

  • 8 Analogue Input Channels
    Measure as many as eight system variables at once with programmable ranges per channel 

  • Differential Analogue Input Configuration
    Enhanced noise immunity and tolerance of common mode voltages.

  • 12- to 16-bit Measurement Resolution

  • Armored Inputs Absorb Mistakes
    Both Analogue and digital inputs are protected

  • Fast 160 kHz Sample Throughput Rate *2

  • Stand-alone Data Logger Operation 
    Store data to flash drives at throughput rates up to 160kHz (requires AC power supply)
    (Note: only with Stand-alone / SA Enabled Option)

  • 15V Excitation
    DI-4108M provides 15V excitation to power sensors.

  • Pre/Post Tigger Storage to USB Memory
    Set trigger levels to record up to 2G (combined) of pre- and post-trigger data (total file size of 4G)

  • Auto Re-Trigger
    When using Triggered Storage, triggers can automatically reset, creating a new file with pre and post-trigger data each time the trigger level is breached.

  • Industrial Oriented
    DI-4108M comes with easy signal swapping connectors, stackable rugged enclosure and ground lug to provide better EMC immunity in harsh environment.

  • Supports ChannelStretch™ Channel Expansion *3
    Connect as many as sixteen DI-4108s , DI-4208s, DI-4718Bs, and/ or DI-4730s to one PC. Synchronously acquire from as many as 128 and 112 Analogue and digital channels respectively.

  • Seven Digital Input Ports
    Folds discrete I/O into the measurement process. Each bit is programmable as an input or as a switch and protected to 0-25 V dc.

  • Asynchronous Digital Switches
    Control external processes seamlessly while acquiring data.

  • Counter Channel
    Tallies the number of pulses applied. Useful for integrating rate information, like flow rate to volume, or simply the number of definable events.

  • Rate Measurement Channel
    Measures pulse rate where frequency carries information. For example: rpm or flow measurements.

  • Optional Power over Ethernet (PoE)
    The optional Power over Ethernet feature allows you to both communicate with and power the DI-4108 via the Ethernet connector, sparing the inconvenience and expense of running power to the unit.

  • Ready-to-run Software Support
    Provided with ready-to-run WinDaq software for point-and-click DAQ performance with a real-time display, disk-streaming recording, and playback and analysis.

 

*1 160,000 S/s in USB mode; 100,000 S/s in Ethernet mode.

*2 160 kHz stand-alone dependent on storage card type – refer to the Specifications Sheet

*3 WinDaq/Unlock required per device to use ChannelStretch™ and to record more than four total channels when using WinDaq software.

Need trigger modes or to stream to Excel directly? Please consider ExcelLink

The post DI-4108-M and DI-4208-M Rugged High-Speed USB/Ethernet Data Loggers appeared first on DAQLOG Systems Ltd.

]]>
DI-2160 8-Ch Event, State, & Count Data Logger https://daqlogsystems.co.uk/product/dataq-di-2160-8-ch-event-state-count-data-logger/ Mon, 11 Sep 2023 11:36:38 +0000 https://daqlogsystems.co.uk/?post_type=product&p=6991
  • Records when, how long, and how many times events occur
  • Reporting interval from 1 second to 1 day, with sampling rate of 10,000 Hz per channel
  • 8 measurement channels, ±170V max, with 1MΩ impedance input protection 
  • The post DI-2160 8-Ch Event, State, & Count Data Logger appeared first on DAQLOG Systems Ltd.

    ]]>
    DI-2160 8-Ch Event, State, & Count Data Logger

    The DI-2160 8-Ch Event, State, & Count Data Logger from DATAQ Instruments is the next generation of DI-160, with eight 1MΩ impedance input channels.

    It features programmable capture modes to detect events (when the events happen), states (how long between events) and counts (how many events). An internal real time clock provides time and date stamping for each captured quantity, and is stored on a removable USB thumb drive. Data storage is in the comma-separated value (CSV) format, so recorded files easily imported to other applications like Microsoft Excel.

    The unit is to be powered by an AC adaptor (included), and SuperCap technology is used to close file properly during sudden power loss. Please note, SuperCap cannot support continuous recording and the last unfinished interval will be lost. A UPS is needed if non-stop operation is desired.

    Product Features

    • Records when, how long, and how many times events occur
    • Reporting interval from 1 second to 1 day, with sampling rate of 10,000 Hz per channel
    • 8 measurement channels, ±170V max, with 1MΩ impedance input protection 
    • Records to removable USB thumb drive in csv (comma-separated value) file format
    • File limit is 4GB, capable of 10,000,000 readings per file
    • Counter is 32-bit integer, capable of 400,000,000 counts per 24 hour interval
    • SuperCap to close file properly for sudden power loss
    • Four measurement modes, state, counter, counter and AC counter.
    • Markings: CE, UKCA

    The post DI-2160 8-Ch Event, State, & Count Data Logger appeared first on DAQLOG Systems Ltd.

    ]]>
    DI-1100 4-Ch USB Data Acquisition Starter Kit https://daqlogsystems.co.uk/product/dataq-di-1100-4-ch-usb-data-acquisition-starter-kit/ Wed, 19 Jul 2023 09:07:39 +0000 https://daqlogsystems.co.uk/?post_type=product&p=6928
  • 4 differential analogue inputs
  • 12-bit measurement resolution
  • ±10 V fixed measurement range
  • up to 40 kHz sampling per channel
  •  

    Also available with ExcelLink

    The post DI-1100 4-Ch USB Data Acquisition Starter Kit appeared first on DAQLOG Systems Ltd.

    ]]>
    DATAQ DI-1100 4-Ch USB Data Acquisition Starter Kit

    The DATAQ DI-1100 4-Ch USB Data Acquisition Starter Kit is a portable data recording module that communicates through your computer’s USB port. Power is derived from the interface port so no external power is required. 

    Product Features

    • 4 fixed differential analogue inputs protected to ±100V (transient).
    • Two dedicated digital I/O ports for Remote control protected to ±30V.
    • ±10V full scale measurement range.
    • 12-bit analogue-to-digital resolution.
    • 20kHz to 40kHz max sample rate per channel (dependent on number of channels enabled).
    • A push-button to tag remote events in WINDAQ software.
    • Three status LEDs for easy notification of system status.
    • Free WinDaq recording and playback software allowing you to record at the full speed of the instrument.
    • Included .Net Class supports programming the DI-1100 under any .Net programming language.
    • Fully documented instrument protocol for programming the device in operating systems other than Windows.
    Analogue Inputs

    The DI-1100 features four differential channel inputs located on a single sixteen-position screw terminal block for easy connection and operation (other terminals used for digital I/O or reserved).

    Note: The DI-1100 does not support Gain.

    Utilize the functionality of WINDAQ software to experience all the features encased in these small, inexpensive instruments.

    Digital Inputs

    The DI-1100 also contains two digital lines (bits) for WINDAQ remote control operations (Remote Start/Stop and Remote Events). Connect switch closures or discrete levels with a maximum input of 30V and a TTL level threshold. The inputs float at 1 level, about 3.3V relative to the “-” terminal, and require sinking about 50uA to bring them down to 0.8V and guarantee a 0.

    When no Options Remote are enabled in WINDAQ, the Event input appears inverted in data bit 0 and the Record input appears inverted in data bit 1 of data for the first enabled channel.

    Software

    All software required to record and playback waveforms is included with the purchase of any DI-1100 data acquisition starter kit via download.

    Need trigger modes or to stream to Excel directly? Please consider ExcelLink

    The post DI-1100 4-Ch USB Data Acquisition Starter Kit appeared first on DAQLOG Systems Ltd.

    ]]>
    DI-2008 Thermocouple and Voltage Data Logger https://daqlogsystems.co.uk/product/dataq-di-2008-thermocouple-and-voltage-data-logger/ Mon, 13 Mar 2023 12:56:42 +0000 https://daqlogsystems.co.uk/?post_type=product&p=6671
  • 8 differential and isolated channels
  • Voltage or TC Type per channel
  • channel expansion to 128 analogue & 112 digital channels
  • The post DI-2008 Thermocouple and Voltage Data Logger appeared first on DAQLOG Systems Ltd.

    ]]>
    8-Channel Thermocouple and Voltage Measurement

    The DATAQ DI-2008 Thermocouple and Voltage Data Logger is a high-performance USB data acquisition system. It is specifically designed for precise temperature and voltage monitoring in industrial, laboratory, and research applications. Featuring 8 differential isolated analogue input channels, the DI-2008 allows each channel to be independently configured for thermocouple or voltage measurements.

    Compatible with Multiple Thermocouple Types

    Supporting thermocouple types J, K, T, B, R, S, E, and N, the DI-2008 provides accurate temperature measurement with automatic linearisation and cold junction compensation. Voltage measurement ranges from ±10 mV to ±50 V make the system suitable for a wide range of signal acquisition tasks, including 4-20 mA process monitoring using a shunt resistor.

    Isolated Inputs for Accurate Industrial Monitoring

    With 16-bit resolution and isolated channel architecture, the DI-2008 delivers highly accurate and noise-resistant measurements, even in electrically noisy industrial environments. The integrated USB interface and included WinDaq software enable rapid setup, real-time monitoring, and reliable long-term data logging.

    The DI-2008 also includes seven programmable digital ports for switch, counter, and rate input applications, making it suitable for RPM, pulse, flow, and event monitoring. Additionally, ChannelStretch™ expansion support allows scalability up to 128 analogue and 112 digital channels for larger data acquisition systems.

    DATAQ DI-2008 thermocouple and voltage data logger

    Ideal Applications for the DATAQ DI-2008

    Ideal for process monitoring, industrial testing, thermal analysis, energy systems, and engineering research. The DATAQ DI-2008 offers flexible and reliable thermocouple and voltage data logging in a compact USB-connected platform.

    DI-2008 Thermocouple and Voltage Data Logger Product Features

    • Eight differential and isolated analogue input channels
    • Seven bi-directional digital input ports, including:
      • Counter input for totalizing applications
      • Rate input for frequency/flow/rpm applications
    • ChannelStretch™ channel expansion to 128 analogue and 112 digital channels (Unlock code required per device)
    • Programmable voltage and thermocouple measurements per channel
    • 10 mV to 50 V programmable range per channel in 12 steps
    • Programmable support for type J, K, T, B, R, S, E, N thermocouples per channel
    • High resolution (16-bit) measurements
    • 2000 Hz max sample throughput for a single channel and 200 Hz for two or more
    • Minimum sample throughput rates as low as 1 sample per day
    • USB interface
    • Included WinDaq software for ready-to-run measurements
    • Included .NET class for Visual Studio program development
    • Fully documented device protocol supports other operating systems

    Need trigger modes or to stream to Excel directly? Please consider ExcelLink

    The post DI-2008 Thermocouple and Voltage Data Logger appeared first on DAQLOG Systems Ltd.

    ]]>
    DI-808 Web-based Voltage and Thermocouple Data Logger https://daqlogsystems.co.uk/product/dataq-di-808-web-based-voltage-and-thermocouple-data-logger/ Mon, 14 Nov 2022 13:00:44 +0000 https://daqlogsystems.co.uk/?post_type=product&p=6278
  • Built-in web server for Any device
  • Access from Anywhere, Anytime
  • Universal analogue inputs
  • Pulse inputs
  • The post DI-808 Web-based Voltage and Thermocouple Data Logger appeared first on DAQLOG Systems Ltd.

    ]]>
    Web-based Voltage and Thermocouple Data Logger from DATAQ Instruments.

    Product Features

    • No software to install
    • Intelligent data logger with built-in web server works with with any device using a modern web browser
    • Stores data locally to internal flash memory or a USB thumb drive and/or remotely to any accessible server or email address
    • Allows remote real time display and configuration
    • 8 differential and isolated analogue input channels programmable as voltage or thermocouple measurement per channel
    • 4 pulse input channels programmable as count, frequency, or discrete function per channel
    • 4 real-time discrete alarm output channels with email/text notification
    • Automatic time and date stamping
    • Flexible triggering selections start and stop data recording based upon
      • Analogue and pulse input levels
      • Alarm status
      • Date/time/day-of-week
    • 20 programmable sampling intervals ranging from 25 mS to 1 hour
    • Built-in Ethernet interface

     

    Web Server

    The DI-808 has a built-in web server which allows you to access, configure, manage, and oversee all aspects of the instrument’s measurement in real time. The Ethernet interface allows integration with any existing local area network (LAN) or virtual private network (VPN.) Using the internet via simple port forwarding allows remote access from any location.

    Data Logger

    8 analogue input channels feature channel-independent voltage and thermocouple configurations. Voltage measurements support ±10 mV to ±50 V measurements across twelve programmable ranges. Thermocouple configurations support J, K, T, B, R, S, E, and N types. Full channel isolation allows virtually any measurement in tough industrial environments, such as: grounded thermocouples, powered thermocouples, off-ground current shunts, as well as unexpected and unknown ground potential differences.

    Complementing the analogue input channels are 4 pulse inputs. Each input can be independently programmed for simple state detection, to operate as a counter, or make a frequency measurement. These allow you to acquire various data types such as volume data from a flow sensor (count), and flow rate (frequency.) Other examples include rpm measurements or simple counting in production or product life test applications.

    Both analogue and pulse measurements are synchronously reported in the same sampling interval, and all measurements are time-and-date-stamped. Program sampling intervals as often as once every 25 mS or as infrequently as once every hour, with 18 selectable intervals in between. There’s even an external option to synchronize sampling to external events.

    Alarm Outputs with E-mail / Text Alerts

    The DI-808 also includes 4 alarm output channels that you can use to flag exceptions during a recording. Each discrete output can be used to signal a PLC, turn on an alarm, or otherwise used as demanded by the application. Each alarm output is also linked to the web interface, where an email alert (or text alert, if supported by your provider) can be triggered when the alarm activates.

     

    The post DI-808 Web-based Voltage and Thermocouple Data Logger appeared first on DAQLOG Systems Ltd.

    ]]>
    DI-4108-E and DI-4208-E High-Speed USB and Ethernet Data Loggers https://daqlogsystems.co.uk/product/dataq-di-4108-e-and-di-4208-e-high-speed-usb-and-ethernet-data-logger/ Mon, 10 Oct 2022 12:36:26 +0000 https://daqlogsystems.co.uk/?post_type=product&p=5981 High-Speed USB and Ethernet Data Loggers DI-4108-E & DI-4208-E from DATAQ.
    Expandable to 128 chs, up to 16-bit resolution where applicable, 160,000 S/s throughput *1.

    The post DI-4108-E and DI-4208-E High-Speed USB and Ethernet Data Loggers appeared first on DAQLOG Systems Ltd.

    ]]>
    High-Speed USB and Ethernet Data Loggers, DI-4108-E and DI-4208-E from DATAQ Instruments.

    DI-4108-E Programmable ranges: ±200, ±500 mV, ±1, ±2, ±5, ±10 V full scale
    DI-4208-E Programmable ranges: ±2, ±5, ±10, ±20, ±50, ±100 V full scale

    Product Features

    • 8 Analogue Input Channels
    • Differential Analogue Input Configuration
      Enhanced noise immunity and tolerance of common mode voltages.
    • 12- to 16-bit Measurement Resolution
    • Armoured Inputs Absorb Mistakes
      Both analogue and digital inputs are protected to 120 Vrms and 0-25 V dc respectively.
    • Fast 160 kHz Sample Throughput Rate *2
    • Stand-alone Data Logger Operation (only with Stand-alone / SA Enabled Option)
      Store data to flash drives at throughput rates up to 160kHz. *2
    • Pre/Post Tigger Storage to USB Memory
      Set trigger levels to record up to 2G (combined) of pre- and post-trigger data (total file size of 4G)
    • Auto Re-Trigger
      When using Triggered Storage, triggers can automatically reset, creating a new file with pre and post trigger data each time the trigger level is breached.
    • Supports ChannelStretch™ Channel Expansion *3
      Connect as many as sixteen DI-4108s , DI-4208s, DI-4718Bs, and/or DI-1120s to one PC. Synchronously acquire from as many as 128 and 112 analogue and digital channels respectively.
    • Seven Digital Input Ports
      Folds discrete I/O into the measurements process. Each bit is programmable as an input or as a switch and protected to 0-25 V dc.
    • Asynchronous Digital Switches
      Control external processes seamlessly while acquiring data.
    • Counter Channel
      Tallies the number of pulses applied. Useful for integrating rate information, like flow rate to volume, or simply the number of definable events.
    • Rate Measurement Channel
      Measures pulse rate where frequency carries information. For example rpm or flow measurements.
    • Ready-to-run Software Support
      Provided with ready-to-run WinDaq software for point-and-click DAQ performance with a real-time display, disk-streaming recording, and playback and analysis.

     

    *1 160,000 s/s in USB mode; 100,000 s/s in Ethernet mode.

    *2 160 kHz stand-alone dependent on storage card type – refer to the Specifications Sheet

    *3 WinDaq/Unlock required per device to use ChannelStretch™ and to record more than four total channels when using WinDaq software.

    Need trigger modes or to stream to Excel directly? Please consider ExcelLink

    Need rugged industrial configuration? Please consider DI-4108-M

    The post DI-4108-E and DI-4208-E High-Speed USB and Ethernet Data Loggers appeared first on DAQLOG Systems Ltd.

    ]]>