UK Supplier of Data Acquisition & Thermal Imaging systems, software and services

Search

µCAN.1.sg-TRS

1-channel analog acquisition module for strain gauge signals with CAN interface.

SKU 16.30.008 Category
Manufacturer:

Call for price

Description

1-Channel CANopen Transmitter for strain gauges. A universal data acquisition module for standard analogue strain gauge signals. The module is designed for strain gauge full bridge signals.
The bridge is powered via the transmitter which can be incorporated into your measuring lines. The analogue signal is sent via short connection lines to the μCAN.1.sg-TRS where the data is digitalized and sent on via CAN-interface to a distributed logging station.

Product Features

  • Strain gauge full bridge
  • Voltage +/- 20 mV
  • Supply voltage 4.5 V
  • Accuracy 0.2% (FS)
  • Resolution 16-bit (1 µV)
  • Sampling rate 20 ms / 50 Hz
  • Supply of the strain gauge full bridge
  • adjustable scaling
  • Fieldbus CAN
  • Protocol CANopen / CAN RAW
I/O per Module 1
Power Supply Voltage 9 - 40VDC, polarity protected
Power Consumption max. 1W (42mA @ 24VDC)
Electrical Isolation ---
Operating Temperature -40°C to +85°C
Transfer Rate 20KBit/sec to 1MBit/sec
Protocol CANopen CiA-404 / CAN 2.0A and 2.0B / others upon request
Number of PDO's 2 transmit PDOs
Configuration Sensor type via field bus
Bit rate and module address via LSS
Status Display ---
Protection Class IP67
Housing Stainless steel circular housing, 22 x 52 mm ( diam. x L )
EMC Complies with EN 50082
Resolution / Sampling Rate 16-bit / 50Hz
Signal Type / Accuracy
@23°C ambient temp
strain gauge full bridge signal, +/-20,000 steps at 3mV/V, accuracy +/- 0.2% fsd
µCAN.1.sg-TRS Specifications µCAN.1.sg-TRS Specifications

µCAN.1.sg-TRS User Manual µCAN.1.sg-TRS User Manual

µCAN.1.sg-TRS Application Note µCAN.1.sg-TRS Application Note