Description
BK 8514B, part of the BK 8500B Series programmable DC electronic loads, improves on its previous model (BK 8500 Series) whilst remaining dependable and affordable. This series supports both SCPI and older protocols.
These DC loads have a transient mode speed of up to 10 kHz and feature various input terminals for banana plug or spade connectors. They are perfect for testing DC power supplies, DC-DC converters, batteries, battery chargers, and solar panels.
Product Features
- Maximum input power of 1500 W
- Operating modes: Constant Current (CC), Constant Voltage (CV), Constant Resistance (CR), and Constant Power (CW)
- Up to 10 kHz transient mode in CC mode
- A 16-bit voltage and current measurement system with a resolution of 0.1 mV / 0.1 mA
- List mode and adjustable rate in CC mode
- Short circuit testing
- A built-in battery test function with voltage level, capacity level, and timer stop options
- CR-LED mode to simulate typical LED loads
- Remote voltage sensing to reduce the impact of voltage drops in wires
- Analogue current control and monitoring
- USB and RS232 interfaces
- Protection features including Over Voltage Protection (OVP), Over Current Protection (OCP), Over Power Protection (OPP), Over Temperature Protection (OTP), and local/remote reverse voltage (LRV/RRV) protection
For faster operation and more PC interface options, check out the B&K Precision 8600 Series DC electronic loads.
Model
|
BK 8514B |
Input Ratings |
Input Voltage |
0 to 120 V |
Input Current |
Low |
0 to 24 A |
High |
0 to 240 A |
Input Power |
1500 W |
Minimum Operating Voltage |
Low |
0.25 V at 24 A |
High |
2.5 V at 240 A |
CV Mode |
Range |
Low |
0.1 to 18 V |
High |
0.1 to 120 V |
Resolution |
Low |
1 mV |
High |
10 mV |
Accuracy |
Low |
±(0.05% + 0.02% FS) |
High |
±(0.05% + 0.025% FS) |
CC Mode |
Range |
Low |
0 to 24 A |
High |
0 to 240 A |
Resolution |
Low |
1 mA |
High |
10 mA |
Accuracy |
Low |
±(0.05% + 0.05% FS) |
High |
±(0.05% + 0.05% FS) |
CR Mode |
Range |
Low |
0.05 Ω to 10 Ω |
High |
10 Ω to 7.5 kΩ |
Resolution |
16 bit |
Accuracy |
Low |
0.01% + 0.08 S (0.01% + 12.5 Ω) |
High |
0.01% + 0.0008 S (0.01% + 1250 Ω) |
CW Mode |
Range |
1500 W |
Resolution |
10 MW |
Accuracy
(Input Current ≥ FS 10%,
Input Voltage ≥ FS 10%) |
±(0.2% + 0.2% FS) |
Transient Mode (CC Mode) |
T1 & T2 *1 |
100 µs to 3600 s/Resolution: 1 µs |
Accuracy |
10 µs ± 100 ppm |
Slew Rate *2 |
Low |
0.001 to 0.3 A/µs |
High |
0.01 to 0.8 A/µs |
*1 Fast pulse trains with large transitions may not be achievable.
*2 The slew rate specifications are not warranted but are descriptions of typical performance. The actual transition time is defined as the time for the input to change from 10% to 90%, or vice versa, of the programmed current values. In case of very large load changes, e.g. from no load to full load, the actual transition time will be larger than the expected time. The load will automatically adjust the slew rate to fit within the range (high or low) that is closest to the programmed value.