DI-2000 Series Archives - DAQLOG Systems Ltd Supplier of data acquisition and thermal imaging cameras Wed, 22 Jul 2026 11:11:48 +0000 en-GB hourly 1 https://wordpress.org/?v=7.1 https://daqlogsystems.co.uk/wp-content/uploads/favicon-196-100x100.png DI-2000 Series Archives - DAQLOG Systems Ltd 32 32 DI-2008 Thermocouple and Voltage Data Logger https://daqlogsystems.co.uk/product/dataq-di-2008-thermocouple-and-voltage-data-logger/ Mon, 13 Mar 2023 12:56:42 +0000 https://daqlogsystems.co.uk/?post_type=product&p=6671
  • 8 differential and isolated channels
  • Voltage or TC Type per channel
  • channel expansion to 128 analogue & 112 digital channels
  • The post DI-2008 Thermocouple and Voltage Data Logger appeared first on DAQLOG Systems Ltd.

    ]]>
    8-Channel Thermocouple and Voltage Measurement

    The DATAQ DI-2008 Thermocouple and Voltage Data Logger is a high-performance USB data acquisition system. It is specifically designed for precise temperature and voltage monitoring in industrial, laboratory, and research applications. Featuring 8 differential isolated analogue input channels, the DI-2008 allows each channel to be independently configured for thermocouple or voltage measurements.

    Compatible with Multiple Thermocouple Types

    Supporting thermocouple types J, K, T, B, R, S, E, and N, the DI-2008 provides accurate temperature measurement with automatic linearisation and cold junction compensation. Voltage measurement ranges from ±10 mV to ±50 V make the system suitable for a wide range of signal acquisition tasks, including 4-20 mA process monitoring using a shunt resistor.

    Isolated Inputs for Accurate Industrial Monitoring

    With 16-bit resolution and isolated channel architecture, the DI-2008 delivers highly accurate and noise-resistant measurements, even in electrically noisy industrial environments. The integrated USB interface and included WinDaq software enable rapid setup, real-time monitoring, and reliable long-term data logging.

    The DI-2008 also includes seven programmable digital ports for switch, counter, and rate input applications, making it suitable for RPM, pulse, flow, and event monitoring. Additionally, ChannelStretch™ expansion support allows scalability up to 128 analogue and 112 digital channels for larger data acquisition systems.

    DATAQ DI-2008 thermocouple and voltage data logger

    Ideal Applications for the DATAQ DI-2008

    Ideal for process monitoring, industrial testing, thermal analysis, energy systems, and engineering research. The DATAQ DI-2008 offers flexible and reliable thermocouple and voltage data logging in a compact USB-connected platform.

    DI-2008 Thermocouple and Voltage Data Logger Product Features

    • Eight differential and isolated analogue input channels
    • Seven bi-directional digital input ports, including:
      • Counter input for totalizing applications
      • Rate input for frequency/flow/rpm applications
    • ChannelStretch™ channel expansion to 128 analogue and 112 digital channels (Unlock code required per device)
    • Programmable voltage and thermocouple measurements per channel
    • 10 mV to 50 V programmable range per channel in 12 steps
    • Programmable support for type J, K, T, B, R, S, E, N thermocouples per channel
    • High resolution (16-bit) measurements
    • 2000 Hz max sample throughput for a single channel and 200 Hz for two or more
    • Minimum sample throughput rates as low as 1 sample per day
    • USB interface
    • Included WinDaq software for ready-to-run measurements
    • Included .NET class for Visual Studio program development
    • Fully documented device protocol supports other operating systems

    Need trigger modes or to stream to Excel directly? Please consider ExcelLink

    The post DI-2008 Thermocouple and Voltage Data Logger appeared first on DAQLOG Systems Ltd.

    ]]>
    DI-2108-P Programmable High-Speed USB DAQ System https://daqlogsystems.co.uk/product/dataq-di-2108-p-programmable-high-speed-usb-daq-system/ Mon, 10 Oct 2022 11:15:28 +0000 https://daqlogsystems.co.uk/?post_type=product&p=5964 Programmable High-Speed USB DAQ System, DI-2108-P from DATAQ Instruments.
    Expandable to 128 chs *1, Stand-alone option. Programmable ranges of ±2.5, ±5, ±10, 0-5, 0-10 V.

    The post DI-2108-P Programmable High-Speed USB DAQ System appeared first on DAQLOG Systems Ltd.

    ]]>
    The DI-2108-P Programmable High-Speed USB DAQ System from DATAQ Instruments.

    Possible alternative product to the discontinued DI-155 model.

    A basic High-Speed USB DAQ System is also available.

    Product Features

    • 8 Analogue Input Channels
      Up to 8 Channels. Programmable ranges per channel are ±2.5, ±5, ±10, 0-5, 0-5 Volts.
    • Differential Analogue Input Configuration
      Enhanced noise immunity.
    • Synchronize Multiple Units *1
      Expand time-aligned channel count by adding more units. (Unlock code required per device)
    • Armoured Inputs Absorb Mistakes
      Analogue inputs are protected to ±150 V and digital inputs up to 25 V.
    • Fast, 160 kHz Sample Throughput Rate
    • 16-bit ADC Resolution
      Supports measurement sensitivity of up to 100 µV on its most sensitive, and 400 µV on its least sensitive range.
    • Stand-alone Data Logger Operation (only with Stand-alone / SA Enabled Option)
    • Store data to flash drives at throughput rates up to 160kHz.  (Unlock Code required to record all channels to USB thumb drive) *2
    • Pre/Post Tigger Storage to USB Memory
      Set trigger levels to record up to 2G (combined) of pre- and post trigger data (total file size of 4G).
    • Seven Digital Ports
      Folds discrete I/O into the measurements process. Each bit is programmable as an input or as a switch.
    • Rate Measurement Channel
      Measures pulse rate as may be acquired from a pickup for rpm measurement, or sensor to measure flow.
    • Counter Channel
      Tallies the number of pulses applied. Useful for integrating rate information, like flow rate to volume, or simply the number of definable events.
    • Software Support
      Supplied with ready-to-run WinDaq software, which records up to four channels at any sampling rate (purchase WinDaq/Unlock to record all channels, or to synchronize multiple units). Also provided with documented command protocol for OS-independent use.

     

    Supplied with: a 6-foot USB cable, a screwdriver for signal connections, and a 32GB USB flash drive containing an NIST-traceable Calibration Certificate and WinDaq software.

    *1 WinDaq/Unlock required per device to use ChannelStretch™ and to record more than four total channels when using WinDaq software.

    *2 160 kHz stand-alone dependent on storage card type – refer to the Specifications Sheet

    Need trigger modes or to stream to Excel directly? Please consider ExcelLink

    The post DI-2108-P Programmable High-Speed USB DAQ System appeared first on DAQLOG Systems Ltd.

    ]]>
    DI-2108 High-Speed USB DAQ System https://daqlogsystems.co.uk/product/dataq-di-2108-high-speed-usb-daq-system/ Mon, 10 Oct 2022 11:14:56 +0000 https://daqlogsystems.co.uk/?post_type=product&p=5943 High-Speed USB DAQ System, DI-2108 from DATAQ Instruments.
    8-Channel High Speed USB Data Acquisition System with Stand-alone Capability (with SA-Enabled option)

    The post DI-2108 High-Speed USB DAQ System appeared first on DAQLOG Systems Ltd.

    ]]>
    The DI-2108 High-Speed USB DAQ System from DATAQ Instruments.

    Possible alternative to the following discontinued products: DI-149, DI-158U, DI-148U, DI-148U-SP, DI-154RS, DI-400 Series and DI-700 Series.

    A Programmable High-Speed USB DAQ System is also available

    Product Features

    • 8 Analogue Input Channels
      With a fixed ±10 V full scale range.
    • Differential Analogue Input Configuration
      Enhanced noise immunity.
    • Anti-alias Filter per Analogue Channel
      Reduces the risk of acquiring meaningless, aliased data. Corner frequency automatically selected at one-tenth of the sampling rate.
    • Armoured Inputs Absorb Mistakes
      Analogue inputs are protected to ±50 V and digital inputs up to 25 V.
    • Fast, 220 kHz Sample Throughput Rate
    • Stand-alone Data Logger Operation (with SA-Enabled option)
      Store data to flash drives at throughput rates up to 160kHz. (Memory card dependant)
    • 12- to 16-bit ADC Resolution
    • Seven Digital Ports
      Folds discrete I/O into the measurements process. Each bit is programmable as an input or as a switch.
    • Rate Measurement Channel
    • Counter Channel
    • Pre/Post Tigger Storage to USB Memory
      Set trigger levels to record up to 2G (combined) of pre- and post-trigger data (total file size of 4G).
    • Software Support
      Provided with ready-to-run WinDaq software – records up to four channels. (Unlock Code required to record all 8 channels using WinDaq.) Also supplied with documented command protocol for OS-independent use.

     

    Supplied with: a 6-foot USB cable, a screwdriver for signal connections, an NIST-traceable Calibration Certificate, and a 32GB USB flash drive with WinDaq software.

    Need trigger modes or to stream to Excel directly? Please consider ExcelLink

    The post DI-2108 High-Speed USB DAQ System appeared first on DAQLOG Systems Ltd.

    ]]>