CAN / CANopen IO Modules https://daqlogsystems.co.uk/product-category/data-acquisition-systems/canbus/i-o-modules/ Supplier of data acquisition and thermal imaging cameras Fri, 23 Jan 2026 12:36:18 +0000 en-GB hourly 1 https://wordpress.org/?v=7.0 https://daqlogsystems.co.uk/wp-content/uploads/favicon-196-100x100.png CAN / CANopen IO Modules https://daqlogsystems.co.uk/product-category/data-acquisition-systems/canbus/i-o-modules/ 32 32 Metric Cable Connection Gland Kit for 8ch BOX Modules https://daqlogsystems.co.uk/product/microcontrol-metric-cable-connection-gland-kit-for-8ch-box-modules/ Wed, 07 Jan 2026 13:09:21 +0000 https://daqlogsystems.co.uk/?post_type=product&p=8821 Metric Cable Connection Gland Kit for 8ch BOX Modules

The post Metric Cable Connection Gland Kit for 8ch BOX Modules appeared first on DAQLOG Systems Ltd.

]]>
Metric Cable Connection Gland Kit for 8ch BOX Modules

Contents:

3 x M16 glands 11-7mm / 7-4mm

2 x M16 blanking plugs

3 x M20 glands

The post Metric Cable Connection Gland Kit for 8ch BOX Modules appeared first on DAQLOG Systems Ltd.

]]>
Metric Cable Connection Gland Kit for 4ch BOX Modules https://daqlogsystems.co.uk/product/microcontrol-metric-cable-connection-gland-kit-for-4-channel-modules/ Wed, 07 Jan 2026 13:06:23 +0000 https://daqlogsystems.co.uk/?post_type=product&p=8818 Metric Cable Connection Gland Kit for 4ch BOX Modules

The post Metric Cable Connection Gland Kit for 4ch BOX Modules appeared first on DAQLOG Systems Ltd.

]]>
Metric Cable Connection Gland Kit for 4ch BOX Modules

Contents:

2 x M16 gland 11-7mm / 7-4mm

1 x M16 blanking plug

4 x M12 gland 8-5mm / 5-2mm

3 x M12 blanking plug

The post Metric Cable Connection Gland Kit for 4ch BOX Modules appeared first on DAQLOG Systems Ltd.

]]>
µCAN.2.ti-TRS https://daqlogsystems.co.uk/product/microcontrol-%c2%b5can-2-ti-trs/ Mon, 27 Jan 2025 11:40:07 +0000 https://daqlogsystems.co.uk/?post_type=product&p=7882 2-channel thermal data acquisition temperature module for Pt100 or Pt1000 with CAN interface.

The post µCAN.2.ti-TRS appeared first on DAQLOG Systems Ltd.

]]>
2-Ch Cable Transmitter Temperature Module.

MicroControl IO module transmitter TRS 2-channel analogue input CANopen

The μCAN.2.ti-TRS cable transmitter is the universal data acquisition module for temperature signals. The module is designed for Pt100 or Pt1000 temperature signals. The transmitter can be incorporated into your measuring lines.
The temperature signal is sent via short connection lines to the μCAN.2.ti-TRS where the data is digitalized and sent on via CAN bus interface to a distributed logging station. 

Product Features

  • Temperature Pt100, Pt1000 (2-wire)
  • Accuracy ± 0.2 K (Pt100)
  • Resolution 16-bit (0.1 °C)
  • Sampling rate up to 1 kHz
  • Sensor error detection
  • Equipped with cold-junction compensation
  • Fieldbus CAN classic / CAN FD
  • Protocol CANopen / CANopen FD / J1939

The post µCAN.2.ti-TRS appeared first on DAQLOG Systems Ltd.

]]>
µCAN.2.sg-TRS https://daqlogsystems.co.uk/product/microcontrol-%c2%b5can-2-sg-trs/ Mon, 27 Jan 2025 10:57:33 +0000 https://daqlogsystems.co.uk/?post_type=product&p=7877 2-channel analogue acquisition module for strain gauge signals with CAN interface.

The post µCAN.2.sg-TRS appeared first on DAQLOG Systems Ltd.

]]>
2-Channel CANopen Transmitter for strain gauges

µCAN.1.sg-TRS Acquisition of strain gauge signals with 16-bit

2-Channel CANopen Transmitter for strain gauges. A universal data acquisition module for standard analogue strain gauge signals. The module is designed for strain gauge full bridge signals.
The bridge is powered via the transmitter which can be incorporated into your measuring lines. The analogue signal is sent via short connection lines to the μCAN.1.sg-TRS where the data is digitalised and sent on via CAN-interface to a distributed logging station. Connection via M 12 circular connectors.

Product Features

  • Strain gauge full bridge
  • Voltage ± 30 mV
  • Supply voltage 4.5 V
  • Accuracy 0.2% (FS)
  • Resolution 16-bit (1 µV)
  • Sampling rate up to 1kHz
  • Supply of the strain gauge full bridge
  • Fieldbus CAN classic / CAN FD
  • Protocol CANopen / CANopen FD / J1939

The post µCAN.2.sg-TRS appeared first on DAQLOG Systems Ltd.

]]>
μCAN.2.ai-TRS https://daqlogsystems.co.uk/product/microcontrol-%ce%bccan-2-ai-trs/ Wed, 27 Nov 2024 14:10:13 +0000 https://daqlogsystems.co.uk/?post_type=product&p=7850 2-channel CANopen analogue acquisition module for voltage or current signals with CAN interface.

The post μCAN.2.ai-TRS appeared first on DAQLOG Systems Ltd.

]]>
2-Ch Cable Transmitter CANopen Module.

Illustration of signal input and CAN supply for µCAN.2.ai-TRS

The μCAN.2.ai-TRS cable transmitter is the universal data acquisition module for standard analogue signals. The module is designed for measuring +/-10V or 0 to 20mA signals. The transmitter can be incorporated into your measuring lines.
The analogue signal is sent via short connection lines to the μCAN.2.ai-TRS where the data is digitalized and sent on via CANbus interface to a distributed logging station. Connection via M12x1 circular connector.

Product Features

  • Voltage ± 10 V
  • Current 0 mA to 20 mA
  • Accuracy 0.01% (FS)
  • Resolution 16-bit (1 mV / 1 µA)
  • Sampling rate up to 1 kHz
  • Sensor supply
  • Fieldbus CAN Classic / CAN FD
  • Protocol CANopen / CANopen FD / J1939

The post μCAN.2.ai-TRS appeared first on DAQLOG Systems Ltd.

]]>
µCAN.2.ti-SENSOR https://daqlogsystems.co.uk/product/microcontrol-%c2%b5can-2-ti-sensor/ Wed, 27 Nov 2024 13:08:12 +0000 https://daqlogsystems.co.uk/?post_type=product&p=7835 2-channel analogue acquisition module for thermocouple and Pt100 / Pt1000.

The post µCAN.2.ti-SENSOR appeared first on DAQLOG Systems Ltd.

]]>
1-Ch Temperature Sensor Module.

The µCAN.2.ti-SENSOR module can be combined with standard pressure sensors. Designed to acquire an analogue sensor signal, the µCAN.2.ti-SENSOR  is integrated into the sensor head (diameter 18 mm). Sensor tolerances can be adjusted with the module already built in. Sensor signals are linearised and supervised via the hardware.

Product Features

  • Temperature Thermo type J, K, L
  • Temperature Pt100, Pt1000 (2-wire)
  • Accuracy ± 0.5 K (Thermo)
  • Accuracy ± 0.2 K (Pt100)
  • Resolution up to 16-bit (0.1 K)
  • Sampling rate up to 1 kHz
  • Signal type freely configurable
  • Sampling rate adjustable
  • Operating temperatures -40 °C to +85 °C
  • Power supply voltage 9 V DC to 36 V DC
  • Fieldbus CAN Classic / CAN FD
  • Protocols CANopen / CANopen FD / J1939