Accessories https://daqlogsystems.co.uk/product-category/data-acquisition-systems/accessories/ Supplier of data acquisition and thermal imaging cameras Mon, 13 Oct 2025 09:56:31 +0000 en-GB hourly 1 https://wordpress.org/?v=6.8.3 https://daqlogsystems.co.uk/wp-content/uploads/favicon-196-100x100.png Accessories https://daqlogsystems.co.uk/product-category/data-acquisition-systems/accessories/ 32 32 Rackmount Kit – DAQ3120 https://daqlogsystems.co.uk/product/bk-sefram-rackmount-kit-daq3120/ Mon, 13 Oct 2025 09:34:43 +0000 https://daqlogsystems.co.uk/?post_type=product&p=8613 Rackmount Kit for the BK DAQ3120

The post Rackmount Kit – DAQ3120 appeared first on DAQLOG Systems Ltd.

]]>
Rackmount Kit – DAQ3120

The kit holds up to two DAQ3120 systems. 2U in size and fits in a standard 19” rack.

The post Rackmount Kit – DAQ3120 appeared first on DAQLOG Systems Ltd.

]]>
2ch Frequency Module https://daqlogsystems.co.uk/product/aandd-2ch-frequency-module/ Fri, 22 Mar 2024 12:35:03 +0000 https://daqlogsystems.co.uk/?post_type=product&p=7377 Frequency Module for RA3100 Data Acquisition System.

The post 2ch Frequency Module appeared first on DAQLOG Systems Ltd.

]]>
2ch Frequency Module for A&D RA3100 Data Acquisition System.

Period, rotation speed, pulse count, etc. can be measured for the input pulse signal.
Measurement result data such as period, rotation speed, pulse count, etc., and the input pulse signal can be saved.

The following measurement modes can be selected for the input pulse signal:

  • Period –  Measures the period of the measured pulse. (s: seconds)
  • Frequency – Measure the frequency of the measured pulse. (Hz: hertz)
  • Rotation speed – Measure the rotation speed of the measured pulse. (rpm: rotations)
  • Pulse width – Measures the pulse width of the measured pulse. (s: seconds)
  • Duty ratio – Measure the duty ratio of the measured pulse. (%: percentage)
  • Power frequency – Measures fluctuations in power supply frequency. (Hz: hertz)
  • Range of variation – Measures the range of variation from the centre frequency. (%: percentage)
  • Pulse count – Counts the number of measured pulses within the gate time. (no.)
  • Pulse integration – Integrates the number of measurement pulses. (no.)

Product Features:

  • 2 Input Channels
  • Input Voltage ±1V to ±500V
  • Measuring Signal – 4 signals (2-channel input signal and 2-channel measurement mode signal)
  • 12bit A/D Resolution
  • 1MS/s Maximum Sampling Speed

The post 2ch Frequency Module appeared first on DAQLOG Systems Ltd.

]]>
2ch High Voltage Module https://daqlogsystems.co.uk/product/aandd-2ch-high-voltage-module/ Thu, 21 Mar 2024 14:27:45 +0000 https://daqlogsystems.co.uk/?post_type=product&p=7369 High Voltage Model for the RA3100 Data Acquisition System.

The post 2ch High Voltage Module appeared first on DAQLOG Systems Ltd.

]]>
2ch High Voltage Module for the RA3100 Data Acquisition System.

This module is capable of ±1,000V high voltage input. Voltage waveform or RMS value can be measured.

Product Features

  • 2 Channels
  • 4MΩ Input Impedance 
  • Voltage measurement mode, RMS measurement mode
  • 2V to 1,000V Measurement Range 
  • RMS conversion time –  High speed: 0.1s, Medium speed: 0.25s, Low speed: 1s
    (in RMS measurement mode)
  • 16bit A/D Resolution
  • 1MS/s max. sampling rate 
  • ±1,000Vpeak maximum allowable input voltage
  • Maximum Rated Voltage to Ground – AC/DC 1,000V CAT II, AC/DC 600V CAT III

The post 2ch High Voltage Module appeared first on DAQLOG Systems Ltd.

]]>
2ch Acceleration Module https://daqlogsystems.co.uk/product/aandd-2ch-acceleration-module/ Thu, 21 Mar 2024 13:30:47 +0000 https://daqlogsystems.co.uk/?post_type=product&p=7359 Acceleration Module for the RA3100 Data Acquisition System.

The post 2ch Acceleration Module appeared first on DAQLOG Systems Ltd.

]]>
2ch Acceleration Module for the RA3100 Data Acquisition System.

This module can measure acceleration, speed, and displacement of mechanical vibration using a piezoelectric acceleration transducer (built-in amplifier, charge output type). The periodicity of impact vibration caused by bearing flaws can be observed using RMS conversion and then envelope processing function.

Product Features

  • 2 Input Channels
  • Measures:
    • acceleration: 1m/s2 to 50km/s2 range,
    • speed: 10mm/s to 500m/s range,
    • displacement: 100μm to 5m range.
  • Amplifier built-in piezoelectric acceleration transducers (charge output type, voltage output type)
  • Charge output type piezoelectric acceleration transducers (charge converter needed)
  • 0.100 to 100.000mV/(m/s2) sensor sensitivity range
  • 16bit A/D resolution
  • 1MS/s maximum sampling speed

The post 2ch Acceleration Module appeared first on DAQLOG Systems Ltd.

]]>
2ch AC Strain Module https://daqlogsystems.co.uk/product/aandd-2ch-ac-strain-module/ Thu, 21 Mar 2024 11:55:31 +0000 https://daqlogsystems.co.uk/?post_type=product&p=7349 Strain Module for the RA3100 Data Acquisition System.

The post 2ch AC Strain Module appeared first on DAQLOG Systems Ltd.

]]>
2ch AC Strain Module for the RA3100 Data Acquisition System.

This input module enables stress measurement using strain gauges as well as strain gauge transducers such as load cells, pressure transducers, and torque transducers. The AC bridge method can be used for measurement that is strong against external noise.

Product Features

  • 2 Input Channels 
  • NDIS4109 Connector (conversion cable sold separately)
  • Bridge Voltage (BV) : 0.5VAC, 2VAC, 5kHz Sine Wave
  • Applicable Strain Gauge Resistance : 120Ω to 350Ω
  • 2 Gauge Rate
  • Equilibrium adjustment range and adjustment method : Within 10,000 x 10-6 strain, Electronic auto balance
  • Maximum Range 500 x 10-6 strain (at BV=2V)
  • Frequency Characteristics DC to 2kHz ±10%
  • Simple Bridge Check
  • 16bit A/D Resolution 
  • Maximum Sampling Speed 100kS/s

The post 2ch AC Strain Module appeared first on DAQLOG Systems Ltd.

]]>
250 Ohm Shunt Resistor for 4-20mA Signals https://daqlogsystems.co.uk/product/dataq-250-ohm-shunt-resistor-for-4-20ma-signals/ Tue, 05 Mar 2024 08:39:26 +0000 https://daqlogsystems.co.uk/?post_type=product&p=7330 R250

4-20mA Current Loop Shunt Resistor.
1/2 W power rating provides safety of excess current up to 45mA.

The post 250 Ohm Shunt Resistor for 4-20mA Signals appeared first on DAQLOG Systems Ltd.

]]>
250 Ohm Shunt Resistor for 4-20mA Signals

250 Ω ±0.1% Precision, 1/2W, Axial Resistor. 1/2 W power rating provides safety of excess current up to 45mA.

 

The post 250 Ohm Shunt Resistor for 4-20mA Signals appeared first on DAQLOG Systems Ltd.

]]>